翻訳と辞書
Words near each other
・ Eleftheros Kosmos
・ Eleftheros Typos
・ Eleftherotypia
・ Eleftheroupoli
・ Eleftheroupoli F.C.
・ Elefun
・ EleFun Games
・ Elefunk
・ Electrostatic loudspeaker
・ Electrostatic motor
・ Electrostatic nuclear accelerator
・ Electrostatic pickup
・ Electrostatic plotter
・ Electrostatic precipitator
・ Electrostatic separator
Electrostatic spray ionization
・ Electrostatic spray-assisted vapour deposition
・ Electrostatic units
・ Electrostatic voltmeter
・ Electrostatic-sensitive device
・ Electrostatics
・ Electrostatic–pneumatic activation
・ Electrosteel Castings
・ Electrostep
・ Electrostephanus
・ Electrostriction
・ Electrostrymon
・ Electrostrymon joya
・ Electrostrymon pan
・ Electrosurgery


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Electrostatic spray ionization : ウィキペディア英語版
Electrostatic spray ionization

Electrostatic spray ionization (ESTASI) is an ambient ionization method for mass spectrometry (MS) analysis of samples located on a flat or porous surface, or inside a microchannel. It was developed in 2011 by Professor Hubert H. Girault’s group at the École Polytechnique Fédérale de Lausanne (EPFL) in Switzerland.〔Qiao, L., Sartor, R., Gasilova, N., Lu, Y., Tobolkina, E., Liu, B. H., Girault, H. H., Anal. Chem. 2012, 84, 7422-7430.〕 In a typical ESTASI process, a droplet of a protic solvent containing analytes is deposited on a sample area of interest which itself is mounted to an insulating substrate. Under this substrate and right below the droplet, an electrode is placed and connected with a pulsed high voltage (HV) to electrostatically charge the droplet during pulsing. When the electrostatic pressure is larger than the surface tension, droplets and ions are sprayed. ESTASI is a contactless process based on capacitive coupling. One advantage of ESTASI is, that the electrode and sample droplet act contact-less avoiding thereby any oxidation or reduction of the sample compounds at the electrode surface, which often happens during standard electrospray ionization (ESI).〔M. Abonnenc, L. Qiao, B. Liu and H. H. Girault, Annual Review of Analytical Chemistry 2010, 3, 231-254.〕 ESTASI is a powerful new ambient ionization technique that has already found many applications in the detection of different analytes, such as organic molecules, peptides and proteins with molecule weight up to 70 kDa.〔Qiao, L., Sartor, R., Gasilova, N., Lu, Y., Tobolkina, E., Liu, B. H., Girault, H. H., Anal. Chem. 2012, 84, 7422-7430.〕 Furthermore, it was used to couple MS with various separation techniques including capillary electrophoresis and gel isoelectric focusing,〔Qiao, L., Sartor, R., Gasilova, N., Lu, Y., Tobolkina, E., Liu, B. H., Girault, H. H., Anal. Chem. 2012, 84, 7422-7430.〕〔Huang G., Li G., Cooks, R. G., Angew. Chem. Int. Ed. 2011, 50, 9907–9910.〕 and it was successfully applied under atmospheric pressure to the direct analysis of samples with only few preparation steps.〔Qiao, L., Tobolkina, E., Liu, B. H., Girault, H. H., Anal. Chem. 2013, 85, 4745-4752.〕
== Principle of operation ==

ESTASI is a contactless electrospray ionization (ESI) method, like dielectric barrier ESI〔Stark A. K., Meyer C., Kraehling T., Jestel G., Marggraf U., Schilling M., Janasek D., Franzke J., Anal. Bioanal. Chem. 2011, 561–569.〕 and induced or inductive ESI.〔Huang G., Li G., Cooks, R. G., Angew. Chem. Int. Ed. 2011, 50, 9907–9910.〕 In ESTASI, an electrode is placed close to a sample only separated by an insulation layer. The sample is covered with a droplet of solution (nano-liters to micro-liters); and a square wave HV is applied between the electrode and the mass spectrometer inlet capillary. Sample ionization occurs and ions are collected for mass spectrometry analysis. The square wave HV can be generated by amplifying the square wave voltage of a function generator. Alternatively, it can be produced by an electric circuit comprising one direct current HV power source and two switches that connect the electrode either to the HV source or to the ground.
When a positive HV is applied to the electrode with respect to the mass spectrometer, a spray of cations is generated out of the droplet containing the sample analytes because of the strong electric filed between the electrode and the mass spectrometer. Excess anions stay inside the droplet on the substrate and are subsequently sprayed when grounding the electrode. In this way, both cations and anions are subsequently measured by mass spectrometry in one experiment.